Brand: MITSUBISHI
Product model: A0J2-56DT
Name: Input/Output Module
Sort: User's Manual
File language: English
File size: 2.84MB
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA A0J2-56DT PDF.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 line /2 line type.
Type of input and output terminal A0J2-56DT
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. RS-232 2 channel.
Transmission speed: 2 channels A0J2-56DT PDF.
At the same time the use of 115.2kbps may.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive A0J2-56DT PDF.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Output points: 32 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: bidirectional thyristor output (type sink).
Response time: 2ms MITSUBISHI User's Manual.
32 points / a common end.
50 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh proocess A0J2-56DT Manual. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read MITSUBISHI User's Manual.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the controll requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A0J2-56DT User's Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A0J2-56DT Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Positioning module
A0J2D71
MITSUBISHI Positioning module A0J2D71
2 axes. 2 axis linear compensation. Control u
MITSUBISHI
AC input / silicon controlled output module
A0J2-E28AS
MITSUBISHI AC input / silicon controlled output module A0J2-E28AS
Input points: 16 points. Input voltage and cu
MITSUBISHI
CPU unit
A0J2HCPU-DC24
MITSUBISHI CPU unit A0J2HCPU-DC24
Input and output points: 480 points. Input /