LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A1SD75P2 User's Manual (Hardware) PDF

MITSUBISHI A1SD75P2 User's Manual (Hardware) PDF

Brand: MITSUBISHI
Product model: A1SD75P2
Name: Positioning Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.23MB
QCPU (Q mode) bus connection.
1 joint.
Applicable models: A985 (-V) /975/970/960GOT. 32 point connector for pressing flat cable (40 pin connector.5 slots A1SD75P2 PDF.
Can be installed in the power supply unit for A series units installed QnA/.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A1SD75P2
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A1SD75P2 PDF.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A1SD75P2 PDF.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest MITSUBISHI User's Manual.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point MITSUBISHI User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centrallized control system I/O points of the estimate A1SD75P2 Manual . Input and output points: 512 points.
Input / output data points: 512 points MITSUBISHI User's Manual.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Optical data communication line function (GI cable).
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a mmeasure of how much the user application can store the number of indicators A1SD75P2 User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words A1SD75P2 Manual . Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
High speed counting module
A1SD62
MITSUBISHI High speed counting module A1SD62
Frequency selection: 100KHZ. Numer of channe
MITSUBISHI
Positioning module
RD75P2
MITSUBISHI Positioning module RD75P2
"Transistor output. Axis of control: 2. Contr
MITSUBISHI
The PC card interface unit
A1SD59J-MIF
MITSUBISHI The PC card interface unit A1SD59J-MIF
SRAM PC card. Applicale models: A95_GOT -M3