MITSUBISHI A1SY81 User's Manual PDF

Brand: MITSUBISHI
Product model: A1SY81
Name: I/O Module
Sort: User's Manual
File language: English
File size: 5.14MB
5 slots.
Can be installed in the power supply unit for A series units installed QnA/.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A1SY81 PDF.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A1SY81
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A1SY81 PDF.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action A1SY81 PDF.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point MITSUBISHI User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30% MITSUBISHI User's Manual.
The following describes the centralized control system I/O points of the estimate. SI/QSI//H-PCF/ wide H-PCF optical cable double loop PC (control station / common station) / remote I/O network (remote master station) A1SY81 Manual. With external power supply function.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI User's Manual.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PPLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A1SY81 Manual A1SY81 User's Manual.
This phenomenon is called the I/O delay time effect.
Related products
MITSUBISHI
Relay output module
A1SY14EU
MITSUBISHI Relay output module A1SY14EU
Output type: relay. Output points: 12 points.
MITSUBISHI
output module
A1SY80
MITSUBISHI output module A1SY80
Output type: transistor source. Output points
MITSUBISHI
Melsecnet interface module
A1SJ71AP21GE
MITSUBISHI Melsecnet interface module A1SJ71AP21GE
PLC station distance: 2Km. Cale type: GI-62.
MITSUBISHI
DC source type input module
A1SX80-S2
MITSUBISHI DC source type input module A1SX80-S2
Type of input: DC source. Input points: 16 po