MITSUBISHI A3NMACA2-UL User's Manual PDF

Brand: MITSUBISHI
Product model: A3NMACA2-UL
Name: PLC
Sort: User's Manual
File language: English
File size: 0.41MB
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA A3NMACA2-UL PDF.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type) A3NMACA2-UL
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. SI/QSI/H-PCF/ wide H-PCF optical cable double loop PC (control station / common station) / reemote I/O network (remote master station) A3NMACA2-UL PDF A3NMACA2-UL Manual . With external power supply function.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A3NMACA2-UL PDF.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three MITSUBISHI User's Manual.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of MITSUBISHI User's Manual.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change off the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI User's Manual A3NMACA2-UL Manual A3NMACA2-UL User's Manual.
This phenomenon is called the I/O delay time effect.