For A6TBXE/A6TBY36E/A6TBX54E/A6TBY54E/A6TBX70E (common cathode; source) long 3m.DC input points: 16 points.
Input voltage and current: 3/7mA, DC12/24V AX10-UL PDF.
Response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public end, 3 point /1 a common end, independent contact AX10-UL
Output form: relay output.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program AX10-UL PDF.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures AX10-UL PDF.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connnected to the input end of the PLC system in a hard wired way, and the timeliness is strong MITSUBISHI User's Manual AX10-UL Manual .
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness MITSUBISHI User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Type of input: DC source.
Input points: 32 points.
Input voltage: 5/12.
Input current: 1.2/3.3mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit MITSUBISHI User's Manual.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control schheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and coomplex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced AX10-UL Manual AX10-UL User's Manual.
Related products
MITSUBISHI
Input module
AX11EU
MITSUBISHI Input module AX11EU
Input points: 32 points. Voltage: AC100 120
MITSUBISHI
AC input / relay output module
AX10Y10C
MITSUBISHI AC input / relay output module AX10Y10C
Input points: 16 points. Input voltage and cu
MITSUBISHI
Input module
AX11C
MITSUBISHI Input module AX11C
Input points: 32 points. Input voltage: AC100
MITSUBISHI
AC input / silicon controlled output module
AX10Y22C
MITSUBISHI AC input / silicon controlled output module AX10Y22C
Input points: 16 points. Input voltage and cu