Brand: MITSUBISHI
Product model: CL1PSU-2A
Name: CC-Link/LT Dedicated Power Supply
Sort: User's Manual
File language: English
File size: 0.37MB
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0 CL1PSU-2A PDF. 1A.
External connection: 2 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. No introductionInput type: DC input, positive public end / negative public end CL1PSU-2A
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0 CL1PSU-2A PDF. 3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Output type: transistor output, source CL1PSU-2A PDF.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module andd electromagnetic valve, etc MITSUBISHI User's Manual CL1PSU-2A Manual. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module.
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. No introductionInput type: DC input, positive common end MITSUBISHI User's Manual.
Input points: 2 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Cable type.
Minimum size of industry.
Can be like a cable, placed in the online slot.
The communication cable and the external equipment connecting cable is a type, and the wiring is simple MITSUBISHI User's Manual.
Communication side, input and output side with cable (50cm). Input type: DC input, positive public end / negative public end.
Input points: 2 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 2 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current:: DC12V/DC24V/0 CL1PSU-2A User's Manual. 1A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL1PSU-2A Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.
Related products
MITSUBISHI
The power adapter
CL1PAD1
MITSUBISHI The power adapter CL1PAD1
Voltage input range: due to different connect
MITSUBISHI
Dedicated power supply
CL1PSU-2A
MITSUBISHI Dedicated power supply CL1PSU-2A
Input voltage rating: AC100/120/230/240V Exte