Brand: MITSUBISHI
Product model: FX2N-10PG
Name: PULSE GENERATOR BLOCK
Sort: INSTALLATION MANUAL
File language: English
File size: 0.20MB
Analog input points: 4 points (type PT100 sensor).
Rated temperature range: -100~600 degree.
Effective digital output: -1000~6000.
Resolution: 0.2~0.3 degree FX2N-10PG PDF.
Weight: 0.1kg.
Dimensions: 17.6 x 90 x 89.5.
Analog quantity input adapter for platinum temperature measuring resistor (PT100 3 wire) temperature sensor.
FX3U-4AD-PTW-ADP through 4 channels, can measure the degree of -100~600.
No programming to send data to FX3 series FX2N-10PG
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U,
Need to convert adapter or function extension board. Needle number: 20.
Specification: loose wire connector, 5 sets (0.3mm 2). Power: 110kw FX2N-10PG PDF.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still bbased on the motor capacity to choose FX2N-10PG PDF FX2N-10PG Manual. ) Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Input and output points: 60 points.
Power supply: AC100-240V.
Input points: 36 points.
Output points: 24 points.
Output form: relay output.
Power consumption: 40W MITSUBISHI INSTALLATION MANUAL.
Weight: 0.85KG.
Outline dimension: 175x90x86mm.
EEPROM memory cartridge with program transfer function.
Third generation standard model.
Easy to use integrated models and flexible scalability.
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control MITSUBISHI INSTALLATION MANUAL.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
Auxiliary relay: 7680 points.
Timer: 320 points.
Counter: 235.
Data register: 8000.
Extended register: 24000 point MITSUBISHI INSTALLATION MANUAL.
Extended file register: 24000.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compaact PLC, simple design and with the basic functions of the FX3 series FX2N-10PG INSTALLATION MANUAL.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model.
High flexiibility FX2N-10PG Manual.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
Related products
MITSUBISHI
Extension module
FX2NC-16EYR-T-DS
MITSUBISHI Extension module FX2NC-16EYR-T-DS
Output points: 16 points. Power supply: the
MITSUBISHI
Positioning module
FX2N-20GM
MITSUBISHI Positioning module FX2N-20GM
Axis of control: 2. Interpolation: there are.
MITSUBISHI
RS-485 expansion board
FX2N-485-BD
MITSUBISHI RS-485 expansion board FX2N-485-BD
Function extension oard for RS-485 communica
MITSUBISHI
Input / output module
FX2N-32ER-ES/UL
MITSUBISHI Input / output module FX2N-32ER-ES/UL
Input and output points: 32 points. Input poi