LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L26CPU-PBT Programming Manual (Special Instructions) PDF

MITSUBISHI L26CPU-PBT Programming Manual (Special Instructions) PDF

Brand: MITSUBISHI
Product model: L26CPU-PBT
Name: PLC
Sort: Programming Manual (Special Instructions)
File language: English
File size: 7.81MB
Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence) L26CPU-PBT PDF.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system L26CPU-PBT
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged L26CPU-PBT PDF.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightniing protection and surge protection function, with 3000V photoelectric isolation L26CPU-PBT Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible L26CPU-PBT PDF.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability MITSUBISHI Programming Manual. IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module MITSUBISHI Programming Manual.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error occurred in the remote station,
AAfter the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network MITSUBISHI Programming Manual L26CPU-PBT Programming Manual.
Even if the power of the system is cut off,, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime L26CPU-PBT Manual.
Related products
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-BT-CM
MITSUBISHI cpu module L26CPU-BT-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro