LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06CCPU-V User's Manual (Multiple CPU System) PDF

MITSUBISHI Q06CCPU-V User's Manual (Multiple CPU System) PDF

Brand: MITSUBISHI
Product model: Q06CCPU-V
Name: CPU
Sort: User's Manual (Multiple CPU System)
File language: English
File size: 9.47MB
RS232 cable for connecting cables and 3M, CPU.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function Q06CCPU-V PDF.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost Q06CCPU-V
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q06CCPU-V PDF.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module Q06CCPU-V PDF.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode MITSUBISHI User's Manual.
In additiion, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q06CCPU-V Manual. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function MITSUBISHI User's Manual.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI User's Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the ssame time Q06CCPU-V User's Manual.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q06CCPU-V Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
C language CPU
Q24DHCCPU-V
MITSUBISHI C language CPU Q24DHCCPU-V
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You can u
MITSUBISHI
C language CPU
Q06CCPU-V-B
MITSUBISHI C language CPU Q06CCPU-V-B
Input / output points: 4096 points. You can u
MITSUBISHI
C language controller module
R12CCPU-V
MITSUBISHI C language controller module R12CCPU-V
Memory capacity: 256MB. As one of the specifi