Name: Channel Isolated Pulse Input Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.29MB
"10BASE-T/100BASE-TX.
Web servo module for RS-232.
Web server module capable of using Internet / Intranet for remote monitoring and operation of programmable controller QD60P8-G PDF.
Use the Internet connected to the PC, just through a simple setup,
Remote monitoring / operation of MELSEC from any location.
Data recording function can be used to display and collect data.
Data can be recorded at the shortest distance of 100ms QD60P8-G
Also has the following functions.
Using email to send data / alarm notification.
Using FTP to transfer / access data files.
The display function of event monitor / history record.
User authentication /IP filter and other security features QD60P8-G PDF.
User can customize the creation of Web pages. "Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.2.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of QD60P8-G PDF MITSUBISHHI User's Manual QD60P8-G Manual.
The photoelectric coupler is composed of two luminous two extreme tubes and a photoelectric transistor.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal MITSUBISHI User's Manual.
The working process of the input interface circuit: when the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light.
When the switch is off, the diode does not emit light, and the transistor is not on the way MITSUBISHI User's Manual. Internal circuit input signal.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal.
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the user application can store the number of indicators QD60P8-G User's Manual.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words QD60P8-G Manual. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.