LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI QJ71C24N-R4 User's Manual (Hardware) PDF

MITSUBISHI QJ71C24N-R4 User's Manual (Hardware) PDF

Brand: MITSUBISHI
Product model: QJ71C24N-R4
Name: Communication Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.45MB
Input / output points: 256 points.
Program capacity: 8 K step.
Processing speed: 0.2 s.
Built in communication port: RS232*1.
Continue to go beyond, to climb the peak of Q series QJ71C24N-R4 PDF.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password QJ71C24N-R4
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights QJ71C24N-R4 PDF.
CPU module expansion standard RAMM (max 8MB) QJ71C24N-R4 Manual.
Can be used with the SD memory card at the same time.
Continuous access file register.Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel QJ71C24N-R4 PDF.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI User's Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected MITSUBISHI User's Manual.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI User's Manual QJ71C24N-R4 User's Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process QJ71C24N-R4 Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
Serial communication module
QJ71C24
MITSUBISHI Serial communication module QJ71C24
"1ch RS-232. 1ch RS-422/485. QJ71C24N -R2 t
MITSUBISHI
Modem interface module
QJ71CMON
MITSUBISHI Modem interface module QJ71CMON
"10BASE-T/100BASE-TX. "A channel modular conn
MITSUBISHI
Serial communication module (upgrade)
QJ71C24N
MITSUBISHI Serial communication module (upgrade) QJ71C24N
RS-232 1 channel. RS-422/485 1 channel. Trans
MITSUBISHI
Modem interface module
QJ71CMO
MITSUBISHI Modem interface module QJ71CMO
Module connector 1Ch. 1ch RS-232. The possii