LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI QJ71C24N User's Manual (Application) PDF

MITSUBISHI QJ71C24N User's Manual (Application) PDF

Brand: MITSUBISHI
Product model: QJ71C24N
Name: Communication Module
Sort: User's Manual (Application)
File language: English
File size: 4.88MB
Master / local station sharing.
Corresponding Ver2 CC-Link.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) QJ71C24N PDF.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of QJ71C24N
Even if the information reaches saturation, it will not affect the link scan time.
The QJ61BT11N module supports CC-Link version 1 and version 2, whiich can be used as a local station or master station module QJ71C24N PDF QJ71C24N Manual. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module QJ71C24N PDF.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode MITSUBISHI User's Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI User's Manual.
Heating function at the same time.
The multiple looop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs MITSUBISHI User's Manual QJ71C24N User's Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process QJ71C24N Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
Serial communication module
QJ71C24
MITSUBISHI Serial communication module QJ71C24
"1ch RS-232. 1ch RS-422/485. QJ71C24N -R2 t
MITSUBISHI
Ethernet module
QJ71E71-100
MITSUBISHI Ethernet module QJ71E71-100
10BASE-T/100BASE-TX. Ethernet interface modul
MITSUBISHI
IE CC-Link controller network module
QJ71GP21-SX
MITSUBISHI IE CC-Link controller network module QJ71GP21-SX
Multimode fier optic cale. Doule circuit.
MITSUBISHI
Optical fiber loop (SI) module
QJ71LP21-25
MITSUBISHI Optical fiber loop (SI) module QJ71LP21-25
SI/QSI/H-PCF/ roadand H-PCF optical cale.