LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI A0J2-E32A datasheet PDF

MITSUBISHI A0J2-E32A datasheet PDF

Brand: MITSUBISHI
Product model: A0J2-E32A
Name: AC input module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/6mA.
External connection: 3 wire.
Spring clamping terminal platform push type input module.
Input module with diagnostic function
The use of push type, do not need screw fastening, so can reduce the wiring hours A0J2-E32A PDF.
Can be used for each 1 points to enter the wiring of the broken wire detection A0J2-E32A
Wiring abnormality of external power supply can be confirmed.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Input points: 16 points.
Voltage: DC12/24V.
Current: 4/10mA A0J2-E32A PDF.
Response time: 6ms/1ms (high speed mode).
8 points / a common end.
Negative utility.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read A0J2-E32A PDF.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control reequirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A0J2-E32A datasheet.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A0J2-E32A datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Bidirectional thyristor output module
A0J2-E24S
MITSUBISHI Bidirectional thyristor output module A0J2-E24S
Output points: 24 points. Voltage: AC100 24
MITSUBISHI
CPU unit
A0J2CPU-DC24
MITSUBISHI CPU unit A0J2CPU-DC24
Input and output points: 480 points. Program
MITSUBISHI
CPU unit
A0J2HCPUR21
MITSUBISHI CPU unit A0J2HCPUR21
Input and output points: 480 points Input / o