LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AJ71E71N-B5T datasheet PDF

MITSUBISHI AJ71E71N-B5T datasheet PDF

Brand: MITSUBISHI
Product model: AJ71E71N-B5T
Name: Network module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Output points: 16 points.
Voltage: DC24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
8 points / a common end.
20 point terminal station.
With short circuit protection.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh AJ71E71N-B5T PDF.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AJ71E71N-B5T
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AJ71E71N-B5T PDF.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive AJ71E71N-B5T PDF.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. 3C-2V/5C-2V coaxial cable.
Double loop.
Remote I/O network (remote control station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLC periphheral hardware circuit AJ71E71N-B5T datasheet.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system compoosed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram AJ71E71N-B5T datasheet.
So far the system''s hardware electrical circuit has been determined.
Related products
MITSUBISHI
Ethernet module
AJ71QE71N-B5T
MITSUBISHI Ethernet module AJ71QE71N-B5T
Ethernet network module 10BASE-T/10BASE5 Equi
MITSUBISHI
Network module
AJ71E71N-B2
MITSUBISHI Network module AJ71E71N-B2
10BASE2. When communicating in the PLC networ
MITSUBISHI
Network module
AJ71E71N-B5
MITSUBISHI Network module AJ71E71N-B5
10BASE5. When communicating in the PLC networ
MITSUBISHI
Ethernet module
AJ71E71N-T
MITSUBISHI Ethernet module AJ71E71N-T
10BASE-T Control layer /MELSECNET/10 H is t