LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-CNB-FLK1AT11 AC/DC24V datasheet PDF

OMRON K3HB-CNB-FLK1AT11 AC/DC24V datasheet PDF

Brand: OMRON
Product model: K3HB-CNB-FLK1AT11 AC/DC24V
Name: Cumulative / increase / decrease pulse meter
Sort: PDF datasheet
File language: English
File size: 1.34MB
Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 24 VAC/VDC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple/Pt100.
Setting unit (setting range): Unit: 1°C/°F (0 to 399°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored K3HB-CNB-FLK1AT11 AC/DC24V PDF K3HB-CNB-FLK1AT11 AC/DC24V
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator. Time specification: Instantaneous type K3HB-CNB-FLK1AT11 AC/DC24V PDF.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K3HB-CNB-FLK1AT11 AC/DC24V PDF.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: relay contact; PASS1c; H, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determinne the color display,
Can switch the green / Red 2 kinds of display colors K3HB-CNB-FLK1AT11 AC/DC24V datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measuremment and identification situations K3HB-CNB-FLK1AT11 AC/DC24V datasheet.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard applicable certification (
Related products
OMRON
Time interval table
K3HB-PNB-FLK3AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK3AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Time interval table
K3HB-PPB-L2AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-L2AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Time interval table
K3HB-PPB-AT11 AC/DC24V
OMRON Time interval table K3HB-PPB-AT11 AC/DC24V
Input type: PNP input type. Event input term