LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-HAA2HHBFD-W User's Manual PDF

OMRON E5EN-HAA2HHBFD-W User's Manual PDF

Brand: OMRON
Product model: E5EN-HAA2HHBFD-W
Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 1.17MB
Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output E5EN-HAA2HHBFD-W PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: - E5EN-HAA2HHBFD-W
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5EN-HAA2HHBFD-W PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV E5EN-HAA2HHBFD-W PDF.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the immplementation of flexible contact output OMRON User's Manual E5EN-HAA2HHBFD-W Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 x 24mm OMRON User's Manual.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: -.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: - OMRON User's Manual.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connectioon method can be selected from a screw terminal and a PUSH-IN fastening terminal E5EN-HAA2HHBFD-W User's Manual.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5EN-HAA2HHBFD-W Manual.
It can be easily set by CS-Thermo (sold separately).
Related products
OMRON
High performance temperature controller
E5EN-HAA2HHBBF-W
OMRON High performance temperature controller E5EN-HAA2HHBBF-W
Size: 48 x 96mm. Category: power AC100 240V
OMRON
High performance temperature controller
E5EN-HAA2HB
OMRON High performance temperature controller E5EN-HAA2HB
Size: 48 x 96mm. Category: power AC100 240V
OMRON
High performance temperature controller
E5EN-HAA2HHBFD-W
OMRON High performance temperature controller E5EN-HAA2HHBFD-W
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
High performance temperature controller
E5EN-HAA2HHBB
OMRON High performance temperature controller E5EN-HAA2HHBB
Size: 48 x 96mm. Category: power AC100 240V