Frequency converter input power: 3 phase AC400V.
Weight: 3.6KG.
Standard applicable line diameter: 8 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor 3G2A5-ID216. Frequency converter input power: 3 phase AC400V.
Weight: 2.1KG.
Stanndard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor 3G2A5-ID216.
Specification: three phase 400V.
Power: 300KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 405kg 3G2A5-ID216.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control OMRON 3G2A5-ID216.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function OMRON 3G2A5-ID216.
Brake transistor built-in.
Protection function. Function name: single phase 200V.
Power: 0.4KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.1KG OMRON 3G2A5-ID216.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):122.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Box protection class: metal, IP00.
Termiinal size: M8 3G2A5-ID216.
Line diameter: 30 square mm.
Weight: 4.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection.