Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Temperature control module >> A1S64TCTT-S1 | MITSUBISHI Temperature control module A1S64TCTT-S1

A1S64TCTT-S1 | MITSUBISHI Temperature control module A1S64TCTT-S1

Brand: MITSUBISHI
Name: Temperature control module
Model: A1S64TCTT-S1
Number of channels: 4 channels.
Sensing methods and temperature range: R, K, J, T, S, B, E, N, U, L, PL, II,, Wre5-26,,, and.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output,
Can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most,
Thermocouple input or PT100 3 wire temperature sensor input,
Control output switching signal for the output of the transistor,
BW is a signal with broken line detection function.

Output type: relay.
Output points: 8 points.
Load voltage: AC240/DC24.
Load current: 2A.
Connection mode: terminal row.
Common public end points: 1.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language MITSUBISHI A1S64TCTT-S1. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system A1S64TCTT-S1
Mainly used for other programming languages more difficult to achieve the user program.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation MITSUBISHI A1S64TCTT-S1.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers MITSUBISHI A1S64TCTT-S1. Poor visibility and operability A1S64TCTT-S1 MITSUBISHI. The main unit of the AS-i system
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A1S64TCTT-S1 MITSUBISHI A1S64TCTT-S1 MITSUBISHI.
This phenomenon is callled the I/O delay time effect A1S64TCTT-S1.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU MITSUBISHI A1S64TCTT-S1.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.