MITSUBISHI A1ST60 User's Manual (Hardware) PDF

Brand: MITSUBISHI
Product model: A1ST60
Name: Analog timer Module
Sort: User's Manual (Hardware)
File language: English
File size: 0.14MB
SUMINET-3200 network.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add A1ST60 PDF.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations A1ST60 Input points: 32 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
32 point /1 a public side.
Positive pole sharing.
Output points: 32 points.
Output voltage: DC24V/AC240V A1ST60 PDF.
OFF leakage current: 0.1mA.
Output response time: 2ms.
Output type: transistor output (type sink).
32 point /1 a public side.
40 pin connector.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requiress 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A1ST60 PDF MITSUBISHI User's Manual A1ST60 Manual .
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor MITSUBISHI User's Manual.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmissionn device, brake signal and fan fault signal A1ST60 User's Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A1ST60 Manual .
Related products
MITSUBISHI
MODBUS interface module
A1SJ71UC24-R2-S2
MITSUBISHI MODBUS interface module A1SJ71UC24-R2-S2
Data format: ASCII. Data its: 7. A1SJ71UC24-
MITSUBISHI
Analog input module
A1S68AD
MITSUBISHI Analog input module A1S68AD
8 channel analog input module. This is a high
MITSUBISHI
Network module
A1SJ71QE71N-B5T
MITSUBISHI Network module A1SJ71QE71N-B5T
Ethernet network module 10BASE-T / 10BASE5.
MITSUBISHI
Serial communication module
A1SJ71QC24-R2
MITSUBISHI Serial communication module A1SJ71QC24-R2
RS-232 2 channel. Transfer speed: 0.3-19.2kp