LK166
Home >> Products >> MITSUBISHI >> Ans/QnAs series PLC >> Computer communication module >> A1SJ71UC24-R2-S2 MITSUBISHI MODBUS interface module

A1SJ71UC24-R2-S2 MITSUBISHI MODBUS interface module

Brand: MITSUBISHI
Name: MODBUS interface module
Model: A1SJ71UC24-R2-S2
Data format: ASCII.
Data bits: 7.
A1SJ71UC24-R2-S2 and A1SJ71UC24-R4-S2 allow the Ans series PLC to be connected to the MODBUS network,
As the network from the station, and in accordance with the instructions of the main station of the CPU Ans user storage area for data reading / writing.
In addition to supporting the MODBUS protocol, these components also support the standard dedicated communication protocol for A1SJ71UC24 components.
This feature makes the main station of the data acquisition and control with more flexibility.
Support MODBUS slave station protocol.
Supports 1 to 21 function code.
Two transmission modes: RTU or ASCII.

3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
Q mode.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A1SJ71UC24-R2-S2 MITSUBISHI A1SJ71UC24-R2-S2
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive A1SJ71UC24-R2-S2 MITSUBISHI.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear A1SJ71UC24-R2-S2 MITSUBISHI.
User memory: user program storage area and work data storage area.
Composed of random access memory (RAM). User use.
Power cut off. Commonly used efficient lithium battery as a backup power supply, life is generally 3~5 years. The telephone line of the interface module is connected with the peripheral equipment.Signal transmission device B/NET interface device for power distribution control equipment
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenonn is called the I/O delay time effect A1SJ71UC24-R2-S2.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU A1SJ71UC24-R2-S2.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.


...More relevant models >>>>