LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-E540-5.5K-CH TECHNICAL MANUAL PDF

MITSUBISHI FR-E540-5.5K-CH TECHNICAL MANUAL PDF

Brand: MITSUBISHI
Product model: FR-E540-5.5K-CH
Name: TRANSISTORIZED INVERTER
Sort: TECHNICAL MANUAL
File language: English
File size: 6.22MB
MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 1.5KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus FR-E540-5.5K-CH PDF.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy FR-E540-5.5K-CH
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure FR-E540-5.5K-CH PDF.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements. Memory format: flash memory.
Number of steps: up to 16000 steps FR-E540-5.5K-CH PDF.
Battery support: do not.
Write, delete method: installed on the PLC through the peripheral devices to write, delete. Length: 3m.
Specification: half pitch 14 pin, D-sub 25 pin (male). Cable length: 3 meters.
For FXCPU (FX0, FX0S, FX0N, FX1S, FX1N, FX2N, FX2NC,) and GOT connection MITSUBISHI TECHNICAL MANUAL.
For FXCPU expansion board FX2N-422-B, FX1N-422-BD and GOT connection. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. "MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 90KW MITSUBISHI TECHNICAL MANUAL.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) MITSUBISHI TECHNICAL MANUAL.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FR-E540-5.5K-CH Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is maiinly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FR-E540-5.5K-CH TECHNICAL MANUAL.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FR-E540-5.5K-CH Manual. "
Related products
MITSUBISHI
3 phase 400V converter
FR-L740-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-L740-5.5K-CHT
MITSUBISHI inverter FR-L740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-5.5K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-F740P-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-5.5K-CHT
"MITSUBISHI inverter FR-F740P series. Voltage
MITSUBISHI
3 phase 400V converter
FR-D740-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-D740-5.5K-CHT
MITSUBISHI inverter FR-D740 series. Voltage l