LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FR-F720P-90K Instruction manual (BASIC) PDF

MITSUBISHI FR-F720P-90K Instruction manual (BASIC) PDF

Brand: MITSUBISHI
Product model: FR-F720P-90K
Name: INVERTER
Sort: Instruction manual (BASIC)
File language: English
File size: 13.09MB
Input points: 4 points.
Weight: 0.02kg.
Function expansion board is used in the FX3SA, FX3S, FX3GA, FX3G, FX3GE on the small number of input and output extension of the product,
Can be built into PLC FR-F720P-90K PDF. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-F720P-90K PDF FR-F720P-90K
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FR-F720P-90K PDF. Connecting cable for handheld GOT and PLC.
Cable length: 1.5 meters.
Application: RS-232C connection (Q series (except for QnU) MITSUBISHI Instruction manual. A 20 pin connector is installed on one side of the loose line.
Length 5M. Power: 30kw.
Voltage: 400V.

There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control FR-F720P-90K Manual .
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost MITSUBISHI Instruction manual.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. The built-in I/O function (Location: 1 axis) of the pulse output is converted to a differential drive output MITSUBISHI Instruction manual. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 400kw.
SLD converter rated current: 962A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
To maximize the performance of the motor.
Advanced auto tuning function.
The newly developed PM motor auto tuning feature can be used to operate other manufacturers of PM motors (Yong Ci synchronous motors) in the sensorless state.
Not only can drive MITSUBISHI induction motor and PM motor, but also can drive other manufacturers of induction motor and PM motor FR-F720P-90K Instruction manual.
This means that you can reduce the cost of inventory and supplies.
If the PM motor is produced by a IPM motor or other company using MM-CF, the starting torque is limited to 50%,
EEven after tuning is not simple to use and positioning control of zero speed torque) induction motor and permanent magnet motor can be combined freely FR-F720P-90K Manual .
Related products
MITSUBISHI
3 phase 200V converter
FR-F720P-45K
MITSUBISHI 3 phase 200V converter FR-F720P-45K
"MITSUBISHI inverter FR-F720P series. Voltage
MITSUBISHI
3 phase 200V converter
FR-F720-5.5K
MITSUBISHI 3 phase 200V converter FR-F720-5.5K
MITSUBISHI inverter FR-F720 series. Voltage l
MITSUBISHI
3 phase 200V converter
FR-F720P-18.5K
MITSUBISHI 3 phase 200V converter FR-F720P-18.5K
"MITSUBISHI inverter FR-F720P series. Voltage
MITSUBISHI
3 phase 200V converter
FR-F720P-15K
MITSUBISHI 3 phase 200V converter FR-F720P-15K
"MITSUBISHI inverter FR-F720P series. Voltage