LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI FX1N-14MR-001 PROGRAMMING MANUAL II PDF

MITSUBISHI FX1N-14MR-001 PROGRAMMING MANUAL II PDF

Brand: MITSUBISHI
Product model: FX1N-14MR-001
Name: PLC
Sort: PROGRAMMING MANUAL II
File language: English
File size: 7.09MB
Max input / output points: 80 points.
Supply voltage: 100 - 240VAC.
Input points: 40 points.
Output points: 40 points.
Output type: Transistor (sinktype) FX1N-14MR-001 PDF.
Power consumption: 50W.
Weight (kg):1.20.
Size (WxHxD) mm:285x90x86.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine FX1N-14MR-001
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system FX1N-14MR-001 PDF.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large capacity, and new features FX1N-14MR-001 PDF.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points. Axis of control: 1.
Instruction speed: 1Hz~1MHz.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V) MITSUBISHI PROGRAMMING MANUAL II.
The maximum 1MHz high speed pulse, can carry on the high speed, high precision positioning.
Can be in the range of 1Hz to 1Hz~1MHz as the interval output pulse.
The high speed moving time can be shortened to 1ms by using a dedicated start input.
Enhanced speed control function MITSUBISHI PROGRAMMING MANUAL II.
Support the approximate S type of acceleration and deceleration function, form operation function, through the maximum 30kHz of the external input pulse rate of synchronization operation, etc.. Input output cable for A6TBXY36 type connector / terminal row conversion module.
Length 3M MITSUBISHI PROGRAMMING MANUAL II. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 11KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is aa power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions FX1N-14MR-001 Manual.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mmainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX1N-14MR-001 PROGRAMMING MANUAL II.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX1N-14MR-001 Manual. "
Related products
MITSUBISHI
PLC
FX2N-16MR-001
MITSUBISHI PLC FX2N-16MR-001
Max input / output points: 16 points. Supply
MITSUBISHI
PLC
FX1N-14MR-D
MITSUBISHI PLC FX1N-14MR-D
Max input / output points: 14 points. Power s
MITSUBISHI
PLC
FX1S-10MR-001
MITSUBISHI PLC FX1S-10MR-001
Total points: 10 points. Input points: 6 poin
MITSUBISHI
Analog output expansion board
FX1N-1DA-BD
MITSUBISHI Analog output expansion board FX1N-1DA-BD
Analog output expansion oard 1 channel. Ca