LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L02CPU-P Programming Guide (Structured Text) PDF

MITSUBISHI L02CPU-P Programming Guide (Structured Text) PDF

Brand: MITSUBISHI
Product model: L02CPU-P
Name: Programmable Controller
Sort: Programming Guide (Structured Text)
File language: English
File size: 2.99MB
Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re L02CPU-P PDF.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0 L02CPU-P3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program L02CPU-P PDF.
No need to use ladder diagram conversion program, can reduce the programming time.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filterr function
Simply set the parameters, you can eliminate the function of the redundant frequency components L02CPU-P PDF L02CPU-P Manual .
Can be selected from low pass filter, high pass filter, medium pass filter.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D converted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened MITSUBISHI Programming Guide. Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function MITSUBISHI Programming Guide.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set MITSUBISHI Programming Guide.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH,, bit 8CH data can be displayed in real time L02CPU-P Programming Guide.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display L02CPU-P Manual .
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog