LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L26CPU-BT-CM Reference Manual (Communication Protocal) PDF

MITSUBISHI L26CPU-BT-CM Reference Manual (Communication Protocal) PDF

Brand: MITSUBISHI
Product model: L26CPU-BT-CM
Name: PLC
Sort: Reference Manual (Communication Protocal)
File language: English
File size: 7.14MB
Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring L26CPU-BT-CM PDF.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm L26CPU-BT-CM
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement L26CPU-BT-CM PDF.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period L26CPU-BT-CM PDF.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Error output.
Rated open and close voltage, current: DC24V,, 0 L26CPU-BT-CM Manual. 5A.
Minimum open and close load: DC5V, 1mA MITSUBISHI Reference Manual.
Response time (OFF, ON): 10ms below.
Response time (ON, OFF): 12ms below.
Life (Mechanical): more than 20 million times.
Life (Electrical) rated open and close voltage, current more than 100 thousand times.
Suitable for wire specifications: 0.3 ~ 2 square mm (AWG22 ~ 14) (twisted pair / single line) MITSUBISHI Reference Manual.
External wiring connection mode: spring clip terminal.
DC5V internal consumption current: 0.06A.
Weight: 0.11kg. Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple MITSUBISHI Reference Manual.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, biit 8CH data can be displayed in real time L26CPU-BT-CM Reference Manual.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display L26CPU-BT-CM Manual.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-BT-CM
MITSUBISHI cpu module L26CPU-BT-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog