LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q170MSCPU-S1 Programming Manual (PID Control Instructions) PDF

MITSUBISHI Q170MSCPU-S1 Programming Manual (PID Control Instructions) PDF

Brand: MITSUBISHI
Product model: Q170MSCPU-S1
Name: PLC
Sort: Programming Manual (PID Control Instructions)
File language: English
File size: 2.84MB
1 slots; no power supply; used to install large PLC series AnS module.
Base plate of AnS series PLC.
QA1S series PLC 1 slot main substrate.
AnS series of modules can be installed Q170MSCPU-S1 PDF. Positioning: 3 axis, built-in counter function, open collector output type.
Control unit: pulse.
Number of location data: 1/ axis.
Maximum output pulse: 100Kpps.
Counter: 3 channels.
100Kpps.
Counter input signal: DV5~24V Q170MSCPU-S1
40 pin connector.
Positioning control using encoder feedback, especially suitable for conveying system and processing machinery, etc..
In the 1 single module, the 3 axis positioning function and the 3 channel counter function are integrated Q170MSCPU-S1 PDF.
Positioning module, high-speed counter module combined as a whole,
Can effectively use the board slot and save space. MODBUS/TCP Master slave station.
10BASE-T/100BASE-TX.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on Q170MSCPU-S1 PDF.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device MITSUBISHI Programming Manual.
Through the linkage function, the master can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-4222/485) of a number of stations for communication Q170MSCPU-S1 Manual.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device with multiple MODBUS communication from the station equipment MITSUBISHI Programming Manual. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)Resolution 262144PLS/res.
Allow speed 3600r/min.
Allowable load of shaft: the maximum of 19.6N, the maximum axial direction is 9.8N.
Convenient processing of large capacity data MITSUBISHI Programming Manual.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming.
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area.
The address register is extended to 32 bits, which can be programmed to go beyond the traditioonal 32K word,
And to achieve the extension to the file register to all regions of the file register Q170MSCPU-S1 Programming Manual.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured daata (array),
The speed has been improved Q170MSCPU-S1 Manual.
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.
Related products
MITSUBISHI
CPU unit
Q2ASHCPU-S1
MITSUBISHI CPU unit Q2ASHCPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
Motion CPU module
Q173DCPU-S1
MITSUBISHI Motion CPU module Q173DCPU-S1
Upgraded version. Control axis: maximum 32 ax
MITSUBISHI
CPU unit
A2ASCPU-S1
MITSUBISHI CPU unit A2ASCPU-S1
I/O points: 512. Processing speed: sec/ 0.2u