LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q172DCPU-S1 Programming Manual (Common Instructions) PDF

MITSUBISHI Q172DCPU-S1 Programming Manual (Common Instructions) PDF

Brand: MITSUBISHI
Product model: Q172DCPU-S1
Name: PLC
Sort: Programming Manual (Common Instructions)
File language: English
File size: 19.95MB
Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2 Q172DCPU-S1 PDF.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q172DCPU-S1
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q172DCPU-S1 PDF.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q172DCPU-S1 PDF.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected MITSUBISHI Programming Manual. Express PCI bus.
Support Japanese, English OS.
Master / local station sharing.
Support Ver.2 CC-Link version.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1 MITSUBISHI Programming Manual. 2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selectted from 2 Q172DCPU-S1 Manual . 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O MITSUBISHI Programming Manual.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmisssion delay time and the application of the synchronization waiting time Q172DCPU-S1 Programming Manual.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Workss2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation Q172DCPU-S1 Manual .
Related products
MITSUBISHI
CPU component
A2SHCPU-S1
MITSUBISHI CPU component A2SHCPU-S1
I/O control method: refresh mode or direct mo
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
CPU unit
A2NCPU-S1
MITSUBISHI CPU unit A2NCPU-S1
Input and output points: 1024 points. Input /