LK166
Home >> Download >> OMRON >> Manual Download >> OMRON 3F88L-160 safety precautions PDF

OMRON 3F88L-160 safety precautions PDF

Brand: OMRON
Product model: 3F88L-160
Name: cam positioner
Sort: safety precautions
File language: English
File size: 0.18MB
Box protection class: metal, IP00.
Terminal size: M8.
Line diameter: 30 square mm.
Weight: 4.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line 3F88L-160 PDF.
Try to be close to the transducer for connection. Function name: 3 phase 400V.
Power: 0.75KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage) 3F88L-160
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function 3F88L-160 PDF.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard 3F88L-160 PDF.
Frequency output up to 580H. Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 6A.
Weight: 0.7KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. Specification: three phase 400V.
Power: 110KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence) OMRON saffety precautions 3F88L-160 Manual.
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 102kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact OMRON safety precautions.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function OMRON safety precautions.
Colorful function.
Brake transistor built-in.
Protection function. Function name: 3 phase 200V.
Power: 3.7KW.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage).
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling: forced cooling.
Weight: 1.9kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication funcction 3F88L-160 safety precautions.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal outpput function for controlling external brake action 3F88L-160 Manual.
Software setting operation mode, no need to connect the control line can be used for speed control.
Related products
OMRON
Safety Light Curtain
MS4800A-30-1600
OMRON Safety Light Curtain MS4800A-30-1600
Numer of eams: 80. Protective height: 1600
OMRON
Crimp plug type
XG4S-1604
OMRON Crimp plug type XG4S-1604
Shape: tension release XG4E. Pole numer: 5
OMRON
Safety Light Curtain
MSF4800A-30-1600
OMRON Safety Light Curtain MSF4800A-30-1600
Numer of eams: 80. Protective height: 1600
OMRON
Cam positioner
3F88L-160
OMRON Cam positioner 3F88L-160
To achieve a more rapid, more advanced rotati