Brand: OMRON
Product model: D4B-3116N
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.32MB
Actuator: Roller plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards D4B-3116N PDF.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4B-3116N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4B-3116N PDF.
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Center roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highhly Sealed D4B-3116N Manual.
Approved by EN, UL, CSA, and CCC (Chinese standard) D4B-3116N PDF.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation OMRON INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now OMRON INSTRUCTION sheet.
Available.
Lineup includes three contact models witth 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4B-3116N INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4B-3116N Manual.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4B-N Series
OMRON Safety Limit Switch D4B-N Series
Roust safety limit switch with metal housing
OMRON
Safety Limit Switch
D4B-4515N
OMRON Safety Limit Switch D4B-4515N
Actuator: Roller lever stainless steel rolle
OMRON
Safety Limit Switch
D4B-2A11N
OMRON Safety Limit Switch D4B-2A11N
Actuator: Roller lever resin roller. Condu
OMRON
Safety Limit Switch
D4B-2170N
OMRON Safety Limit Switch D4B-2170N
Actuator: Plunger. Conduit openings: G1/2 P