LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-1125 INSTRUCTION sheet PDF

OMRON D4N-1125 INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4N-1125
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches D4N-1125 PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-1125
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4N-1125 PDF.
Certified standards: UL, EN (TÜV), and CCC. Head material: Plastic.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and reelease types: Mechanical lock Solenoid release D4N-1125 PDF D4N-1125 Manual.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+1NC/1NO.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility OMRON INSTRUCTION sheet.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20 OMRON INSTRUCTION sheet.
IP67 degree of protection.
Variety of Metallic Heads Available. Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Side plunger, Adjustable.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) OMRON INSTRUCTION sheet.
Wide stanndard operating temperature range:
-40°C to +100°C (standard type) D4N-1125 INSTRUCTION sheet.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-1125 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Related products
OMRON
Safety Limit Switch
D4N-2BLE
OMRON Safety Limit Switch D4N-2BLE
Actuator: Fork lever lock left operation.
OMRON
Safety Limit Switch
D4N-9B31
OMRON Safety Limit Switch D4N-9B31
Actuator: Plunger. Conduit size: 1-conduit
OMRON
Pull-reset Safety Limit Switch
D4N-6A20R
OMRON Pull-reset Safety Limit Switch D4N-6A20R
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-2225
OMRON Safety Limit Switch D4N-2225
Actuator: Roller lever resin lever, metal ro