Brand: OMRON
Product model: D4N-2B62R
Name: pull-reset safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC D4N-2B62R PDF.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC+1NC/1NO D4N-2B62R
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4N-2B62R PDF.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degrree of protection D4N-2B62R Manual.
Variety of Metallic Heads Available D4N-2B62R PDF. Ratings: 3 A.
Actuator: Hinge lever.
Terminals: Molded lead wire terminals (300 mm).
Contact form: SPDT.
Sealed Subminiature Basic.
Switch Conforming to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing,
making this switch ideal for places subject to,
water spray or excessive dust OMRON INSTRUCTION sheet.
Ideal for automobiles, automatic vending,
machines, refrigerators, ice-making equipment,
bath equipment, hot-water supply systems, air,
conditioners, and industrial equipments, which,
require high environmental resistance.
Models available with UL, CSA, and VDE safety,
standard compliance OMRON INSTRUCTION sheet. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Top plunger, Adjustable.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) OMRON INSTRUCTION sheet.
Wide standdard operating temperature range:
-40°C to +100°C (standard type) D4N-2B62R INSTRUCTION sheet.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-2B62R Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Related products
OMRON
Safety Limit Switch
D4N-1F22
OMRON Safety Limit Switch D4N-1F22
Actuator: Roller lever metal lever, resin ro
OMRON
Safety Limit Switch
D4N-8E72
OMRON Safety Limit Switch D4N-8E72
Actuator: One-way roller arm lever vertical
OMRON
Pull-reset Safety Limit Switch
D4N-8A2HR
OMRON Pull-reset Safety Limit Switch D4N-8A2HR
Actuator: Adjustale roller lever, form lock
OMRON
Pull-reset Safety Limit Switch
D4N-9B31R
OMRON Pull-reset Safety Limit Switch D4N-9B31R
Actuator: Plunger. Conduit size: 1-conduit