LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-3B62 INSTRUCTION sheet PDF

OMRON D4N-3B62 INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4N-3B62
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Actuator: Plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards D4N-3B62 PDF.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-3B62
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4N-3B62 PDF.
Certified standards: UL, EN (TÜV), and CCC. Input type: Platinum-resistance thermometer input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality.
The Temperature Input Terminal can be used with almost the same functionality as a D4N-3B62 PDF.
Analog Input Terminal, such as with scaling and comparator functions.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels OMRON INSTRUCTION sheet.
Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards OMRON INSTRUCTION sheet.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connnector models are also available, saving on labor and,
simplifying replacement D4N-3B62 Manual.
Standardized gold-clad contacts provide high contact reliability OMRON INSTRUCTION sheet.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key innsertion point D4N-3B62 INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-3B62 Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-4ERE
OMRON Safety Limit Switch D4N-4ERE
Actuator: Fork lever lock right operation.
OMRON
Pull-reset Safety Limit Switch
D4N-1C72R
OMRON Pull-reset Safety Limit Switch D4N-1C72R
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-4D80
OMRON Safety Limit Switch D4N-4D80
Actuator: Cat whisker. Conduit size: 1-condu
OMRON
Pull-reset Safety Limit Switch
D4N-1D31R
OMRON Pull-reset Safety Limit Switch D4N-1D31R
Actuator: Plunger. Conduit size: 1-conduit