LK166
Home >> Download >> OMRON >> Manual Download >> OMRON D4SL-N2RFG-D INSTRUCTION sheet PDF

OMRON D4SL-N2RFG-D INSTRUCTION sheet PDF

Brand: OMRON
Product model: D4SL-N2RFG-D
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.63MB
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches D4SL-N2RFG-D PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4SL-N2RFG-D
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N2RFG-D PDF.
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) D4SL-N2RFG-D PDF.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL aand CSA-certified cables D4SL-N2RFG-D Manual.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation OMRON INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release OMRON INSTRUCTION sheet.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inserttion point D4SL-N2RFG-D INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N2RFG-D Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.