LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E3ZM-LS67X INSTRUCTION sheet PDF

OMRON E3ZM-LS67X INSTRUCTION sheet PDF

Brand: OMRON
Product model: E3ZM-LS67X
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 22.48MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M : 4m E3ZM-LS67X PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E3ZM-LS67X
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Classification: General purpose Models E3ZM-LS67X PDF.
Description: Sheathed thermocouple.
Temperature range (See note 3.): 0°C to 900°C.
Element type: K (CA) J (IC).
Conductor type: Non grounded type.
Class: 2 (0.75).
Protective tubing material: ASTM316L.
Terminal type: Exposed lead wires.
Page: 9 to 12.
A Wide Variety of High-precision E3ZM-LS67X PDF.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON INSTRUCTION sheet. Size: 48 x 96mm E3ZM-LS67X Manual.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling OMRON INSTRUCTION sheet.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo)) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3ZM-LS67X INSTRUCTION sheet.
Through the infrared port can be carried out from the frront of the communication E3ZM-LS67X Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-LS89H
OMRON Compact Photoelectric Sensor  E3ZM-LS89H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-D62
OMRON Compact Photoelectric Sensor  E3ZM-D62
Sensing method: Diffuse reflective. Connecti
OMRON
Compact Photoelectric Sensor
E3ZM-D67
OMRON Compact Photoelectric Sensor  E3ZM-D67
Sensing method: Diffuse reflective. Connecti
OMRON
Compact Photoelectric Sensor
E3ZM-T66
OMRON Compact Photoelectric Sensor  E3ZM-T66
Sensing method: Through eam Emitter Recei