LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-HTAA2HH01BD-FLK INSTRUCTION Manual PDF

OMRON E5EN-HTAA2HH01BD-FLK INSTRUCTION Manual PDF

Brand: OMRON
Product model: E5EN-HTAA2HH01BD-FLK
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 1.84MB
Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: PUSH-IN fastening terminal table type E5EN-HTAA2HH01BD-FLK PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5EN-HTAA2HH01BD-FLK
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10 E5EN-HTAA2HH01BD-FLK PDF. 5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5EN-HTAA2HH01BD-FLK PDF.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric ccommunication conversion Village (sold separately) connected to the computer after,
No power connection can be set E5EN-HTAA2HH01BD-FLK Manual.
It can be easily set by CS-Thermo (sold separately) OMRON INSTRUCTION Manual. Case color: Black.
Control output: Relay output.
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-RTC;
Resistance thermometer input, E5GN-RP OMRON INSTRUCTION Manual.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 OMRON INSTRUCTION Manual. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-HTAA2HH01BD-FLK INSTRUCTION Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-HTAA2HH01BD-FLK Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
High performance temperature controller
E5EN-HSS2HH01BD-FLK
OMRON High performance temperature controller E5EN-HSS2HH01BD-FLK
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
Programmed temperature controller
E5EN-HTAA2HB
OMRON Programmed temperature controller E5EN-HTAA2HB
Size: 48 x 96mm. Category: power AC100 240V
OMRON
Programmed temperature controller
E5EN-HTAA2HH03B-FLK
OMRON Programmed temperature controller E5EN-HTAA2HH03B-FLK
Size: 48 x 96mm. Category: power AC100 240V
OMRON
Programmed temperature controller
E5EN-HTAA2HHBBFD
OMRON Programmed temperature controller E5EN-HTAA2HHBBFD
Size: 48 x 96mm. Type: power AC/DC24V with. S