Brand: OMRON
Product model: KS1-ANDC-SW90
Name: Ionizer
Sort: PDF datasheet
File language: English
File size: 8.83MB
Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element KS1-ANDC-SW90 PDF.
Burnout Detector compatible with a,
wide-range of heater control methods KS1-ANDC-SW90
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance KS1-ANDC-SW90 PDF.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note KS1-ANDC-SW90 PDF. ).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Rated primary current: 600 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Allarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor KS1-ANDC-SW90 datasheet.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss KS1-ANDC-SW90 datasheet.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
Related products
OMRON
Ionizer
KS1-ANDC50
OMRON Ionizer KS1-ANDC50
Product: Flexile Tue Nozzle 500 mm. Wide
OMRON
Ionizer
KS1-ANDC-FT90
OMRON Ionizer KS1-ANDC-FT90
Product: 90° Flexile Flat Nozzle Cap. Wide
OMRON
Ionizer
KS1-ANFT90
OMRON Ionizer KS1-ANFT90
Product: 90° Flat Nozzle. Wide Range of Nozz
OMRON
Ionizer
KS1-ANNS-U
OMRON Ionizer KS1-ANNS-U
Product: 500-mm Conductive Urethane Tue. Wi