LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI A1SX71 datasheet PDF

MITSUBISHI A1SX71 datasheet PDF

Brand: MITSUBISHI
Product model: A1SX71
Name: DC source type input module
Sort: PDF datasheet
File language: English
File size: 1.60MB
Output type: transistor source.
Output points: 16 points.
Load voltage: DC12/24.
Load current: 0.8A.
Connection mode: terminal row.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC A1SX71 PDF.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order A1SX71
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic A1SX71 PDF.
And the control principle is decentralized, centralized and hybrid control three. RS-422 connection (QnA/A/FXCPU direct connection, computer connection, micro computer connection).
No clock function.
Applicable models: A985 (-V) /975/970/960GOT. Write adapter for EPROM 28 pinOutput type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0 A1SX71 PDF. 1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Coaxial data communication line function.
AnNCPU command processing time and ACPU compare to 10-20% high speed processing.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions forr 2~4 A1SX71 datasheet.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure A1SX71 datasheet.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
32: terminal line adapter
A1S-TB32
MITSUBISHI 32: terminal line adapter A1S-TB32
The 32 point pressure terminal line adapter t
MITSUBISHI
Positioning control module
A1SD75P1-S3
MITSUBISHI Positioning control module A1SD75P1-S3
Axis of control: 1. A1SD75 series components
MITSUBISHI
Extension cable
A1SC01B
MITSUBISHI Extension cable A1SC01B
Cale length: 0.055 meters. Extending cale t