LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AJ71QC24N-R4 datasheet PDF

MITSUBISHI AJ71QC24N-R4 datasheet PDF

Brand: MITSUBISHI
Product model: AJ71QC24N-R4
Name: Serial communication module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Enter 32 points.
2/5mA DC12/24V.
Response time: 10ms.
32 point 1 public.
Output 32 points.
DC12/24V.
Leakage current: 0.1mA OFF.
Response time: 1ms.
32 point 1 public.
Protection function.
Surge.
40 pin connector.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC AJ71QC24N-R4 PDF AJ71QC24N-R4
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control AJ71QC24N-R4 PDF.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Input points: 16 points.
Voltage: DC100/110/125V.
Current: 2mA.
Response time: 20ms.
8 points / a common end.
Positive / negative sharing.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh AJ71QC24N-R4 PDF.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requiirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ71QC24N-R4 datasheet.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ71QC24N-R4 datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Serial communication module (upgrade)
QJ71C24N-R4
MITSUBISHI Serial communication module (upgrade) QJ71C24N-R4
RS-422/485. 2 channel. Transmission speed: 2
MITSUBISHI
Serial communication module
AJ71QC24
MITSUBISHI Serial communication module AJ71QC24
RS-232 1 channel, RS-422/485 1 channel. Trans
MITSUBISHI
Serial communication module
AJ71QC24N-R2
MITSUBISHI Serial communication module AJ71QC24N-R2
RS-232 2 channel. Transmission speed: 2 chann
MITSUBISHI
Serial communication module
AJ71QC24N
MITSUBISHI Serial communication module AJ71QC24N
RS-232 1 channel, RS-422/485 1 channel. Trans