Brand: MITSUBISHI
Product model: CL9-TERM
Name: Terminal resistance
Sort: PDF datasheet
File language: English
File size: 8.82MB
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 1 wire.
MIL connector type.
Minimum size of industry.
Relay terminal, terminal station conversion module and electromagnetic valve, etc CL9-TERM PDF. are connected to a simple MIL connector.
Simply remove the connector can be replaced with a simple module CL9-TERM
Additional module power supply, I/O power sharing.
No additional I/O power supply, you can reduce the cost and set space. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA CL9-TERM PDF.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Output type: relay output CL9-TERM PDF.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
External connection: 1 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 16 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DDC12V/DC24V/0 CL9-TERM datasheet. 1A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL9-TERM datasheet.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.
Related products
MITSUBISHI
Terminal interface module
AJ71C21-S1
MITSUBISHI Terminal interface module AJ71C21-S1
RS-232:1 channel, RS-422:1 channel. BASIC pro
MITSUBISHI
Terminal module
FX-32E-TB
MITSUBISHI Terminal module FX-32E-TB
Enter 32 points or 32 points Divided into 16
MITSUBISHI
Screw terminal type output module
CL1Y4-R1B2
MITSUBISHI Screw terminal type output module CL1Y4-R1B2
Output type: relay output. Output points: 4 p