LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI FX3S-30MT/ESS datasheet PDF

MITSUBISHI FX3S-30MT/ESS datasheet PDF

Brand: MITSUBISHI
Product model: FX3S-30MT/ESS
Name: PLC
Sort: PDF datasheet
File language: English
File size: 11.82MB
Input / output type: DC input (drain / source).
Input and output points: 16 points.
DC5V internal consumption current: 100mA.
DC24V internal consumption current: 85mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 FX3S-30MT/ESS PDF.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FX3S-30MT/ESS MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FX3S-30MT/ESS PDF.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FX3S-30MT/ESS PDF.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 315KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to thhe change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FX3S-30MT/ESS datasheet FX3S-30MT/ESS datasheet.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.
Related products
MITSUBISHI
PLC
FX3U-16MT/ESS
MITSUBISHI PLC FX3U-16MT/ESS
Max input / output points: 16 points. Supply
MITSUBISHI
PLC
FX3U-80MT/ESS
MITSUBISHI PLC FX3U-80MT/ESS
Max input / output points: 80 points. Supply
MITSUBISHI
PLC
FX5U-80MT/ESS
MITSUBISHI PLC FX5U-80MT/ESS
Function: CPU module internal service power
MITSUBISHI
PLC
FX3U-64MT/ESS
MITSUBISHI PLC FX3U-64MT/ESS
Max input / output points: 64 points. Supply