LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON E2E-X2MY1-Z 2M datasheet PDF

OMRON E2E-X2MY1-Z 2M datasheet PDF

Brand: OMRON
Product model: E2E-X2MY1-Z 2M
Name: Standard Proximity Sensor
Sort: PDF datasheet
File language: English
File size: 7.56MB
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2 E2E-X2MY1-Z 2M PDF.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: - E2E-X2MY1-Z 2M
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E2E-X2MY1-Z 2M PDF.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E2E-X2MY1-Z 2M PDF.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of aapplications E2E-X2MY1-Z 2M datasheet.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E2E-X2MY1-Z 2M datasheet.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Related products
OMRON
Standard Proximity Sensor
E2E-X2MF1-M3-Z
OMRON Standard Proximity Sensor E2E-X2MF1-M3-Z
Appearance: M8. Sensing distance: 2 mm. Con
OMRON
Standard Proximity Sensor
E2E-X2MY2-Z 2M
OMRON Standard Proximity Sensor E2E-X2MY2-Z 2M
Appearance: M8. Sensing distance: 2 mm. Con
OMRON
Standard Proximity Sensor
E2E-X2ME1-M3-Z
OMRON Standard Proximity Sensor E2E-X2ME1-M3-Z
Appearance: M8. Sensing distance: 2 mm. Con
OMRON
Standard Proximity Sensor
E2E-X2MF1-M1-Z
OMRON Standard Proximity Sensor E2E-X2MF1-M1-Z
Appearance: M8. Sensing distance: 2 mm. Con