LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-PNB-L2AT11 AC100-240 datasheet PDF

OMRON K3HB-PNB-L2AT11 AC100-240 datasheet PDF

Brand: OMRON
Product model: K3HB-PNB-L2AT11 AC100-240
Name: Time interval table
Sort: PDF datasheet
File language: English
File size: 1.59MB
Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz K3HB-PNB-L2AT11 AC100-240 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-PNB-L2AT11 AC100-240
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
Rotation measurement of high speed rotating objects can be carried out.
SupportSetting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0 K3HB-PNB-L2AT11 AC100-240 PDF. 8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-PNB-L2AT11 AC100-240 PDF.
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is iindicated from the start of operation K3HB-PNB-L2AT11 AC100-240 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-PNB-L2AT11 AC100-240 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products