LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-VLC-E-DRT1 AC100-240 datasheet PDF

OMRON K3HB-VLC-E-DRT1 AC100-240 datasheet PDF

Brand: OMRON
Product model: K3HB-VLC-E-DRT1 AC100-240
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Type of input: AC voltage input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-VLC-E-DRT1 AC100-240 PDF.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC-E-DRT1 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviCategory: external supply 100mA DC5V type K3HB-VLC-E-DRT1 AC100-240 PDF.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-VLC-E-DRT1 AC100-240 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied toIdeal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-VLC-E-DRT1 AC100-240 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-E-DRT1 AC100-240 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Voltage and current panel meter
K3HB-XVA-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-DRT1 AC100-240
Type of input: AC voltage input. Output type
OMRON
Time interval table
K3HB-PNB-A-DRT1 AC100-240
OMRON Time interval table K3HB-PNB-A-DRT1 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Temperature panel
K3HB-HTA-DRT1 AC100-240
OMRON Temperature panel K3HB-HTA-DRT1 AC100-240
Type of input: platinum resistance / thermoco