LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K8DS-PA1 datasheet PDF

OMRON K8DS-PA1 datasheet PDF

Brand: OMRON
Product model: K8DS-PA1
Name: Three-phase Asymmetry and Phase-sequence Phase-loss Relay
Sort: PDF datasheet
File language: English
File size: 0.99MB
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8DS-PA1 PDF.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8DS-PA1
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8DS-PA1 PDF. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual K8DS-PA1 PDF.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DDC24V K8DS-PA1 datasheet.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input caan be applied to a variety of measurement and identification situations K8DS-PA1 datasheet.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
U