LK166
Home >> Download >> OMRON >> Manual Download >> OMRON C500-RT002-PEV1 SETUP MANUAL PDF

OMRON C500-RT002-PEV1 SETUP MANUAL PDF

Brand: OMRON
Product model: C500-RT002-PEV1
Name: Safety Light Curtain
Sort: SETUP MANUAL
File language: English
File size: 1.04MB
CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 12; Output, 8 C500-RT002-PEV1 PDF.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet C500-RT002-PEV1
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams C500-RT002-PEV1 PDF. UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable C500-RT002-PEV1 PDF.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-232C ports; CCommunications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave OMRON SETUP MANUAL C500-RT002-PEV1 Manual.
No. of unit numbers allocated: 1 OMRON SETUP MANUAL.
Current consumption : 5V, 0.28A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol OMRON SETUP MANUAL. Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 4 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settablee to 1/4,000);
Conversion speed, 250 s/point max C500-RT002-PEV1 SETUP MANUAL.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Anaalog Input Units for converting,
analog input signals into binary data C500-RT002-PEV1 Manual.
Analog Output Units for converting ,
binary data into analog output signals.
Related products
OMRON
SYSBUS Remote I/O Unit
C500-RT002-V1(3G2A5-RT002-V1)
OMRON SYSBUS Remote I/O Unit C500-RT002-V1(3G2A5-RT002-V1)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi
OMRON
SYSBUS Remote I/O Unit
C500-RT201(3G2A5-RT201)
OMRON SYSBUS Remote I/O Unit C500-RT201(3G2A5-RT201)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi
OMRON
SYSBUS Remote I/O Unit
C500-RT001-V1(3G2A5-RT001-V1)
OMRON SYSBUS Remote I/O Unit C500-RT001-V1(3G2A5-RT001-V1)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi
OMRON
SYSBUS Remote I/O Unit
C500-RT001-PV1(3G2A5-RT001-PV1)
OMRON SYSBUS Remote I/O Unit C500-RT001-PV1(3G2A5-RT001-PV1)
C500-RT SYSMAC BUS Remote I/O Master Slave Wi