LK166
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-HTA-BCD1 Communications Manual PDF

OMRON K3HB-HTA-BCD1 Communications Manual PDF

Brand: OMRON
Product model: K3HB-HTA-BCD1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.76MB
Static type reverse electric relay K2FW type.
Ensure high accuracy digital UFR/OFR.
Constitute by the crystal oscillator plus digital IC,
Can achieve high accuracy of frequency detection (adjustment, detection accuracy of less than 0 K3HB-HTA-BCD1 PDF. 1HZ).
50-60HZ share, can be adjusted arbitrarily in the range of 45-65HZ through the surface of the dial switch plate.
Because of the high speed detection, the low frequency relay can detect the system accident before the under voltage relay K3HB-HTA-BCD1 Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input K3HB-HTA-BCD1 PDF.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-HTA-BCD1 PDF.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurableRated input voltage: 3-phase 3-wire mode, 380, 400, 415, or 480 VAC OMRON Communications Manual.
Ideal for Monitoring 3-phase Power Supplies,
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, phase sequence, and phase loss,
in three-phase three-wire circuits with one unit K3HB-HTA-BCD1 Manual.
One SPDT output relay, 5 A at 250 VAC (resistive load) OMRON Communications Manual.
World-wide power specifications supported by one unit.
(Set with a rotary switch.).
Relay status can be monitored using LED indicator. Models: OCR-H (51).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched OMRON Communications Manual.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal trributaries K3HB-HTA-BCD1 Communications Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-HTA-BCD1 Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-BCD1 AC100-240
OMRON Voltage and current panel meter K3HB-XAA-BCD1 AC100-240
Type of input: AC current input. Output type
OMRON
Temperature panel
K3HB-HTA-T11 AC100-240
OMRON Temperature panel K3HB-HTA-T11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-FLK3AT11 AC100-240
OMRON Temperature panel K3HB-HTA-FLK3AT11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-L2AT11 AC100-240
OMRON Temperature panel K3HB-HTA-L2AT11 AC100-240
Type of input: platinum resistance / thermoco