LK166
Home >> Supply >> CJ1W-B7A14 B7A Interface Unit OMRON CJ1W-B7A14
Search
Information sort

CJ1W-B7A14 B7A Interface Unit OMRON CJ1W-B7A14


Supply voltage: 100 to 240 V AC, 50/60 Hz (wide range).
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 3.6 A(18 W).Power supply voltage: DC100V.
Note: operation with output contacts.
Power supply unit.
The power supply of the CPU rack is supplied by the power supply unit CJ1W-B7A14.
The following power units are available for selection..
C200HW-PA204 (voltage: AC100-120V/AC200-240V)
C200HW-PA204S (voltage: AC100-120V/AC200-240V)
C200HW-PA204R (voltage: AC100-120V/AC200-240V)
C200HW-PD024 (voltage: DC24V)
In the past, PC connected to a measurement equipment or components must be given to the ASCII unit or BASIC unit to write a communication program CJ1W-B7A14.
Now, PC C200HX/HG/HE is installed on the communication protocol macro function,
Can be configured to these communications procedures through the PMCR instruction to the ladder program,
With this function system can be easily connected with a wide range of components CJ1W-B7A14.
Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 inputs;
External connection, Removable terminal block OMRON CJ1W-B7A14.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications OMRON CJ1W-B7A14.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator OMRON CJ1W-B7A14. Output method: Analog resolution: 1/6000.
Analog Inputs: 4.Unit classification: CJ1 CPU Bus Unit.
Product name: SPU Unit,
(High-speed Data Storage Unit).
Specifications:PC Card slot,
CF Card Type I/II × 1 slot,
Use an OMRON HMCEF@@@Memory Card;
Ethernet (LAN) port,
1 port(10/100Base-TX).
No. of unit numbers allocated: 1.
Current consumption: 5V , 0.56A;
24V, --.
Standards: UC1, CE.
High-speed Collection of System Data,
The CPU Unit can collect large amounts,
of process data, operation data,
inspectiion data, and other controlled,
system data quickly and automatically,
save the data in external storage,
media as CSV files CJ1W-B7A14. Model: C200H-OC226N.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).

Related supply information