LK166
Home >> Supply >> CQM1-PD026 OMRON DC Power Supply Module CQM1-PD026
Search
Information sort

CQM1-PD026 OMRON DC Power Supply Module CQM1-PD026


Communications protocol: Dedicated CompoBus/S protoco.
Code: Manchester code.Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CQM1-PD026.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CQM1-PD026.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
Supply voltage: 24 V DC CQM1-PD026.
Operating voltage range: 20 to 28 V DC.
Output capacity: 30 W 5 V DC: 6 A.Protector for Expansion I/O Rack IOIF connector CV500-COV02Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA OMRON CQM1-PD026.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON CQM1-PD026.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON CQM1-PD026.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CQM1-PD026.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Related supply information