LK166
Home >> Supply >> FX2N-48ET | MITSUBISHI Transistor output unit FX2N-48ET
Search
Information sort

FX2N-48ET | MITSUBISHI Transistor output unit FX2N-48ET


MITSUBISHI inverter FR-E740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 0.4KW.
Allow short-time overload (200% 3S).
The machine itself does not need to purchase another operating panel.
Provide USB interface to connect with the computer, you can use the FRConfigurator software to set the parameters of the inverter or monitor FX2N-48ET.
Inverter surface with PU interface, FR-E500 operating panel can be directly connected to the E700 series. The installation dimensions are in full agreement with FR-E500 FX2N-48ET.
Allow side by side installation, saving installation space
Simple maintenance: equipped with comb type wiring board, wiring more convenient, the replacement of the same series inverter, no stitches, as long as the original inverter control terminal MITSUBISHI FX2N-48ET. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output FX2N-48ET.Function extension board for RS-422 communication.
No DC24V consumption, no occupancy of the input output (FX1S and FX1N of the host computer) MITSUBISHI FX2N-48ET. Maximum frequency: 200kHz.
Input points: 2 points.
Output form: transistor 4 point output.
Weight: 0.2kg.
1 FX3U-2HC can enter the 2CH high speed signal, can achieve the maximum count of 200kHz.
Through the comparison of the value of the PLC set, each ch with 2 points of high-speed output terminal MITSUBISHI FX2N-48ET.
In the 2 phase count, can be set 1, 2, 4 frequency.
Can be achieved by PLC or external input to count the licensing / prohibition.
Can also be connected to the linear drive output type of the encoder.
FX3UC host connected to the FX2NC-CNV-IF, the need for FX3U-2HC or FX3UC-IPS-5V. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 55kw.
SLD converter rated current: 316A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the auttomatic adjustment of water FX2N-48ET.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display.

Related supply information