LK166
Home >> Supply >> OMRON CJ1W-PD025 CJ-series Power Supply Unit OMRON CJ1W-PD025
Search
Information sort

OMRON CJ1W-PD025 CJ-series Power Supply Unit OMRON CJ1W-PD025


Model: CPM2C-20CDT1M-D. CPU Unit: Units with 20 I/O points.
2 MIL connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 12; Output, 8 CJ1W-PD025 CJ1W-PD025.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CJ1W-PD025.
Product name: DC Power Supply Unit.
Power supply voltage: 24 VDC. 5A;
24-VDC output capacity, 0.8A;
Total power consumption, 25w.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecast monitor, No OMRON CJ1W-PD025.
Standards: UC1, N, L, CE.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement.
notification function for easy,
maintenance.
Lineup of five models including the,
AC power supply (25W) OMRON CJ1W-PD025.
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options. Name: Three-tier Screw Terminal Block OMRON CJ1W-PD025.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participatioon Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CJ1W-PD025. vFor 10-slot Backplane.NO. OF I/O SLOTS: 6 SLOTSC500-CP Special I/O Unit Cam Positioner Unit C500-CP131.

Related supply information